
Peptides
DSIP
Buy 2, get 1 free10mg
$54.99
Welcome to VANTA LABS
Are you 21 or older?
Vanta Labs supplies research materials for laboratory use only. You must be 21 or older to enter.
Research use only. Not for human or veterinary use.

BPC-157 is a synthetic pentadecapeptide, a chain of 15 amino acids with the sequence Gly-Glu-Pro-Pro-Pro-Gly-Lys-Pro-Ala-Asp-Asp-Ala-Gly-Leu-Val. Vanta Labs supplies it as a lyophilized powder in 5 mg and 10 mg vials. The website currently lists separate Certificate of Analysis reports for each size. This product is intended exclusively for laboratory research and is not for human consumption, veterinary use, or any application outside a controlled research setting.
Molecular Formula: C62H98N16O22
Amino Acid Sequence
GEPPPGKPADDAGLVPurity
99.736%
Batch
Vanta184290
Published batch records
Vanta184290
10 mg · 99.759% · Aug 24, 2026 · Kovera Labs
Vanta184290
5 mg · 99.736% · Aug 24, 2026 · Kovera Labs
Frequently Asked Questions
BPC-157 is a synthetic pentadecapeptide: a chain of 15 amino acids, supplied by Vanta Labs as a lyophilized powder for laboratory research use only.
Yes. BPC-157 is classified as a synthetic peptide, specifically a pentadecapeptide made of 15 amino acid residues joined in a single chain.
BPC-157 contains 15 amino acids, which is what makes it a pentadecapeptide.
The sequence is GEPPPGKPADDAGLV in one-letter notation, or Gly-Glu-Pro-Pro-Pro-Gly-Lys-Pro-Ala-Asp-Asp-Ala-Gly-Leu-Val in three-letter notation.
GEPPPGKPADDAGLV (Gly-Glu-Pro-Pro-Pro-Gly-Lys-Pro-Ala-Asp-Asp-Ala-Gly-Leu-Val), 15 amino acids.
The CAS number listed for BPC-157 is 137525-51-0, corresponding to the free-base chemical reference entry.
The molecular formula of BPC-157 is C62H98N16O22.
The molecular weight of BPC-157 is 1419.5 g/mol.
CAS 137525-51-0, molecular formula C62H98N16O22, and molecular weight 1419.5 g/mol, as listed by PubChem (CID 9941957).
BPC-157 is listed on PubChem under CID 9941957.
Vanta Labs currently offers BPC-157 in 5 mg and 10 mg vials.
BPC-157 is supplied as a lyophilized (freeze-dried) powder.
Yes. The 5 mg and 10 mg vials are each documented under their own report, issued independently by Kovera Labs for its own batch and size. Match the batch and size on the vial to the matching report in the COA Library before relying on any figure.
No. The Vanta Labs product page identifies BPC-157 as not approved by the U.S. Food and Drug Administration (FDA) as a drug. Regulatory status outside the United States is not addressed here, and BPC-157 is sold strictly for laboratory research use, not for human or veterinary use of any kind.
Yes. BPC-157 has been named in Section S0 (Non-Approved Substances) of WADA's Prohibited List since the 2022 List. This is a separate fact from, and in addition to, its lack of FDA approval.
No. All compounds sold by Vanta Labs are strictly for legitimate laboratory research purposes and are not intended for human or veterinary use.
Where a batch report has been published, the product page links to it. All published reports are in the COA Library, searchable by batch number.
In-stock orders placed before 2PM ET on a business day are dispatched the same day. Carrier transit time is additional. You will receive secure tracking information after dispatch.
No — exactly one discount applies per order. Promo codes, ambassador codes, bundle pricing, and promotions never combine. You don't have to figure out which is best: checkout automatically applies whichever single discount saves you the most.
Where we ship, damaged or missing items, returns and support are covered in our FAQ.
Related Products
BPC-157 is cataloged as a synthetic pentadecapeptide: a defined chain of 15 amino acid residues joined by peptide bonds. The name is used consistently across chemical databases, including PubChem, to refer to this specific sequence. Classifying a compound this way is a statement about molecular structure, not about how the compound behaves in any system. Vanta Labs lists BPC-157 strictly as a research chemical, supplied for use by qualified personnel in laboratory settings.
The term "pentadecapeptide" describes a peptide built from exactly 15 amino acids linked in a single chain, no more and no fewer. BPC-157 earns this classification because the sequence contains 15 amino acid residues. This is a structural description only. It says nothing about biological activity, mechanism, or outcome, and none of that is implied by the terminology.
The one-letter sequence for BPC-157 is GEPPPGKPADDAGLV. Written in three-letter notation, this reads as Gly-Glu-Pro-Pro-Pro-Gly-Lys-Pro-Ala-Asp-Asp-Ala-Gly-Leu-Val. Each code corresponds to a standard amino acid: glycine (Gly), glutamic acid (Glu), proline (Pro), lysine (Lys), alanine (Ala), aspartic acid (Asp), and leucine (Leu), with valine (Val) closing the chain. This sequence is identical across both vial sizes Vanta Labs offers. Only the total mass supplied in the vial changes between the 5 mg and 10 mg options, not the sequence itself.
"BPC-157" is the name most consistently used across chemical reference sources and research literature for this pentadecapeptide. It is also recorded under the synonyms "Pentadecapeptide BPC-157," "Body Protection Compound-157," "PL 14736," "PL-10," and "PLD-116." These names identify the same chemical entity. Neither the name nor any of its synonyms implies any approved status, clinical classification, or biological outcome; they exist to keep identification consistent across documentation, ordering, and laboratory recordkeeping.
| Identifier | Value |
|---|---|
| CAS Number | 137525-51-0 |
| PubChem CID | 9941957 |
| FDA UNII | 8ED8NXK95P |
The CAS number above corresponds to the free-base reference entry for BPC-157. A separate FDA chemical reference document lists BPC-157 acetate under a different CAS number (216441-37-1). The exact counter-ion or salt form of the material in this specific vial is not independently confirmed by manufacturer documentation, so no salt-form claim is made here. See the identity note below for that distinction.
| Property | Value |
|---|---|
| Molecular Formula | C62H98N16O22 |
| Molecular Weight | 1419.5 g/mol |
These values describe the free-base chemical reference structure. As noted above, the supplied material's exact salt form has not been separately confirmed, so these figures should be read as chemical reference data rather than a certified specification of the physical vial contents.
Vanta Labs currently lists BPC-157 in two sizes: 5 mg and 10 mg, each supplied in its own vial. These are two distinct package options, not two different compounds or concentrations of a combined formulation. Each size is documented and tested independently.
BPC-157 is supplied as a lyophilized (freeze-dried) powder. This is a description of the physical form the material ships in, not instructions for handling, reconstitution, or use. Any such instructions fall outside the scope of this research-use-only listing.
Vanta Labs documents the 5 mg and 10 mg BPC-157 vials separately, each under its own laboratory report. The live product page displays the documentation for the batch presently in stock; that documentation applies to the current batch only, and is not a permanent specification carried forward to every future batch.
The 5 mg and 10 mg vials each carry their own Certificate of Analysis, issued independently by Kovera Labs. The two documents are specific to their respective size and should not be combined, averaged, or treated as interchangeable. A figure from one report does not apply to the other, and neither figure should be read as a guarantee for any future batch. Full reports, including access details, are available through the COA Library rather than in this general description.
Each report's purity figure comes from reversed-phase high-performance liquid chromatography (RP-HPLC) using a C18 column with diode array detection at 214 nm. Identity confirmation is performed separately using liquid chromatography-mass spectrometry (LC-MS). These two figures, the RP-HPLC purity figure and the LC-MS identity confirmation, are reported individually for each size and reflect laboratory testing methodology, not clinical quality or safety for use in or on a living organism. Vanta Labs also states a general purity guarantee as a commercial policy. This guarantee is a store-level assurance and is distinct from the specific analytical figure published for the current batch; it should not be read as a substitute for the batch-specific documentation available in the COA Library.
BPC-157, as supplied by Vanta Labs, is intended exclusively for legitimate laboratory research conducted by qualified personnel in appropriate research settings. It is not for human consumption, not for veterinary use, not a drug, not a food, not a cosmetic, and not a dietary supplement. It is not intended for personal use of any kind, and it is not intended to diagnose, treat, cure, or prevent any condition.
BPC-157 is not approved by the U.S. Food and Drug Administration. Separately, it has also been named in Section S0 (Non-Approved Substances) of the World Anti-Doping Agency's Prohibited List, beginning with the 2022 List. This is a distinct regulatory fact from FDA approval status, and applies independently of it; it is noted here because it is directly relevant to anyone subject to anti-doping rules.
This product has not been evaluated for safety or efficacy in humans or animals outside of a controlled research context, and no statement on this page should be read as suggesting otherwise. Buyers are responsible for ensuring their use of this material complies with all applicable laws and regulations in their jurisdiction. For current analytical documentation, refer to the Certificate of Analysis for the specific batch and size purchased.
Blog
Verified purchases
I have now successfully ordered and received many products that have proven to be exactly what I hoped for. The Customer Service has been amazing. The orders are processed and shipped immediately. I received my first order in less than 24 hours after I ordered it. I can’t say enough good things about this place.
Verified buyer · Nov 15, 2026
Store reviews · ordering, shipping and service
5.0 average customer rating
“Ordered on a Wednesday morning and wasn't expecting much because it was my first time buying here. Got tracking that afternoon and the package arrived Friday. Honestly faster than I expected lol.”
Vanta Labs customer
“Not gonna lie I accidentally added the wrong item to my cart and didn't realize until after checkout. Sent a message thinking I'd be stuck with it. Support helped me correct it before the package went out. Saved me a headache.”
Vanta Labs customer
“The packaging was actually what impressed me most. I've had glass research supplies arrive with barely any protection before, so seeing everything packed properly was a relief. Little things like that matter.”
Vanta Labs customer
“First time ordering here. The site was easy enough to use, although I had to go back and double check which size I selected. Everything was labeled clearly when it arrived.”
Vanta Labs customer
“Honestly I spent more time comparing options than I did checking out lol. Once I decided what I wanted, the actual order process took maybe two minutes.”
Vanta Labs customer
“Placed an order after a friend mentioned the website. I was a little skeptical because I hadn't heard of them before, but the ordering experience was straightforward and the communication was good. Everything came fast and will buy again.”
Vanta Labs customer
Sent to us by customers by email; names withheld. Reviews describe ordering, shipping and service.
Specifications
GEPPPGKPADDAGLVGly-Glu-Pro-Pro-Pro-Gly-Lys-Pro-Ala-Asp-Asp-Ala-Gly-Leu-ValThe listed CAS number reflects the BPC-157 free-base reference entry. The FDA's chemical reference document separately lists BPC-157 acetate under CAS 216441-37-1. The exact salt form and counter-ion of the supplied material are not confirmed by manufacturer documentation, so no salt-form claim is made for this product.
Source: PubChem CID 9941957 · FDA Global Substance Registration System (GSRS), UNII 8ED8NXK95P · FDA chemical reference document · World Anti-Doping Agency, 2022 Prohibited List. Accessed 2026-11-11.
Testing
Certificates of Analysis for the batch currently supplied. Each report is the laboratory's own document for that vial size.
KVR-2026-6B1171 · 5 mg · Batch Vanta184290
Purity 99.736% (RP-HPLC, C18 column, DAD detection at 214 nm) · Identity by LC-MS · Certified Aug 24, 2026 · Kovera Labs
Access code FJQ6M7K
KVR-2026-C2D666 · 10 mg · Batch Vanta184290
Purity 99.759% (RP-HPLC, C18 column, DAD detection at 214 nm) · Identity by LC-MS · Certified Aug 24, 2026 · Kovera Labs
Access code UB6XFLA
Kovera Labs reports can be checked with the laboratory: enter the report number and access code at koveralabs.com/verify.
Browse the COA LibraryOrdering: Shipping policy · Returns and reimbursement · Research use disclaimer