Selank is a synthetic heptapeptide built by extending the tuftsin sequence (Thr-Lys-Pro-Arg) with Pro-Gly-Pro, giving the seven-residue chain TKPRPGP. It carries CAS number 129954-34-3, molecular formula C33H57N11O9, and a molecular weight near 751.9 g/mol. Vanta Labs supplies Selank as a 10 mg lyophilized powder in a sealed vial. This product is intended for legitimate laboratory research only, not for human or veterinary use, consumption, or administration.
Molecular Formula: C33H57N11O9
Amino Acid Sequence
TKPRPGPPurity
99.254%
Batch
Vanta184290
Published batch records
Vanta184290
10 mg · 99.254% · Aug 24, 2026 · Kovera Labs
Frequently Asked Questions
TKPRPGP, written in three-letter notation as Thr-Lys-Pro-Arg-Pro-Gly-Pro. The first four residues are the tuftsin fragment Thr-Lys-Pro-Arg, extended with Pro-Gly-Pro. CAS 129954-34-3, C33H57N11O9, 751.9 g/mol, as listed by PubChem (CID 11765600).
No. It is not listed in the FDA's Drugs@FDA database. Vanta Labs supplies it for laboratory research only. It is not for human or veterinary use.
Check the amino acid sequence, CAS number, and molecular formula listed in the specifications table against the compound you are comparing. Selank carries CAS 129954-34-3 and the sequence TKPRPGP. Semax and N-Acetyl Selank are distinct peptides with different sequences and CAS numbers, so a difference in those values means a different compound.
The label on your vial identifies the product and the batch number. Matching that batch number and vial size to the Certificate of Analysis in the COA Library connects your vial's labeling to the published report for that specific batch. The report then provides the laboratory's analytical findings for the sample it tested. A label or chemical identifier on its own does not independently prove the physical contents of a vial; the matching COA is the documentation that speaks to the tested sample.
The CAS number, 129954-34-3, is a chemical registry identifier for this exact structure, and the molecular formula, C33H57N11O9, describes its elemental composition. The amino acid sequence, TKPRPGP, adds further structural identification. These identifiers describe the specified chemical entity; they do not by themselves prove the contents of any particular vial or laboratory sample. Analytical testing, documented in a batch's Certificate of Analysis, is a separate part of assessing a tested sample's identity.
The molecular weight, approximately 751.9 g/mol, is a chemical property expressed in grams per mole and describes the mass of one mole of the Selank molecule. It is not the same figure as the labeled 10 mg quantity in the product vial, which refers to the net weight of material supplied.
Selank is supplied as a 10 mg lyophilized powder in a single sealed vial.
The reported purity comes from reverse-phase HPLC, which separates the sample's components and estimates purity from the relative areas of the detected peaks for the tested batch. It is a chromatographic estimate for that specific sample, not a direct measurement of the exact mass percentage of Selank in every vial, and it applies only to the batch named in its report. Published reports on this site do not test for sterility, endotoxins, residual solvents, heavy metals, or water content, and a report's silence on those tests is not evidence that the sample passed or failed them.
LC-MS, liquid chromatography-mass spectrometry, compares the measured mass of the tested sample against the compound's expected mass to support the identity assessment. Identity and purity answer different questions, so a sample can match the expected compound while still containing impurities, or show no detected impurities while still being the wrong compound. LC-MS does not independently establish purity, sterility, or other quality characteristics.
No. A Certificate of Analysis documents only the specific sample, batch, and labeled vial size identified on that report. If you are supplied a different batch or a different package size, look up the report matching the batch number on your own vial in the COA Library.
N-Acetyl Selank is a chemically modified derivative of Selank and should not be treated as identical to, or interchangeable with, the unmodified Selank listed on this page. Always confirm the exact compound name, sequence, and CAS number on any listing or Certificate of Analysis before comparing products.
Research Use Only means Selank is supplied strictly for laboratory and research applications. It is not intended for human or veterinary use, consumption, or administration, and it is not a dietary supplement, food, or cosmetic.
No. All compounds sold by Vanta Labs are strictly for legitimate laboratory research purposes and are not intended for human or veterinary use.
Where a batch report has been published, the product page links to it. All published reports are in the COA Library, searchable by batch number.
In-stock orders placed before 2PM ET on a business day are dispatched the same day. Carrier transit time is additional. You will receive secure tracking information after dispatch.
No — exactly one discount applies per order. Promo codes, ambassador codes, bundle pricing, and promotions never combine. You don't have to figure out which is best: checkout automatically applies whichever single discount saves you the most.
Where we ship, damaged or missing items, returns and support are covered in our FAQ.
Related Products

Peptides
5mg · 10mg
$29.99

Peptides
10mg
$54.99

Peptides
50mg
$29.99

Peptides
1mg
$79.99
Selank belongs to a class of synthetic peptides derived from tuftsin, a naturally occurring tetrapeptide fragment (Thr-Lys-Pro-Arg). Selank extends that fragment with three additional residues, Pro-Gly-Pro, producing the full seven-residue sequence Thr-Lys-Pro-Arg-Pro-Gly-Pro, commonly abbreviated TKPRPGP. This structural relationship is why Selank is classified as a tuftsin analog.
The compound carries the CAS registry number 129954-34-3, the molecular formula C33H57N11O9, and a molecular weight of approximately 751.9 g/mol. These identifiers are consistent across independent chemical databases and are listed in full in the Product Specifications section below.
Vanta Labs supplies Selank as a 10 mg lyophilized powder, sealed in a single vial. Lyophilized powder is a freeze-dried supplied form.
This listing is for Selank specifically. Selank is a distinct compound from Semax and from N-Acetyl Selank. The three are sometimes searched together because they are related research peptides, but they have different sequences and different CAS numbers and are not interchangeable.
This product is supplied strictly for legitimate laboratory research. It is not for human use, not for veterinary use, not for consumption or administration, and is not intended to diagnose, treat, cure, or prevent any disease. It is not a dietary supplement, food, or cosmetic.
| Specification | Value |
|---|---|
| Product name | Selank |
| CAS number | 129954-34-3 |
| PubChem CID | 11765600 |
| Molecular formula | C33H57N11O9 |
| Molecular weight | 751.9 g/mol |
| Amino acid sequence | TKPRPGP |
| Three-letter sequence | Thr-Lys-Pro-Arg-Pro-Gly-Pro |
| Compound type | Synthetic heptapeptide (tuftsin analog) |
| Supplied form | Lyophilized powder |
| Product quantity | 10 mg |
| Package type | Vial |
These values describe the compound itself. The documented testing figure for the current production batch is covered in the Quality, Purity & Handling section below.
A published report is currently listed for the Selank 10 mg batch. This documentation applies only to the sample, batch, and vial size identified in that report. A different batch or a different vial size requires its own matching documentation, and a future production run is not covered by this report until its own COA is published.
RP-HPLC is a chromatographic separation method commonly used for this compound's batch documentation, typically with a C18 column and diode-array detection. The method separates the sample's components, and the reported purity figure is an area-based estimate calculated from the relative areas of the detected peaks. This is not an exact measurement of the mass percentage of Selank in the entire vial, and it applies to the tested sample named in the report, not to all batches or future production.
LC-MS (liquid chromatography-mass spectrometry) provides mass-spectrometric information used for identity assessment. Identity and purity answer different questions: a sample can match the expected compound while still containing impurities, or show no detected impurities while still being the wrong compound. Neither test on its own establishes sterility, endotoxin status, residual solvents, heavy metals, water content, or overall product safety. Published reports on this site do not test for sterility, endotoxins, residual solvents, heavy metals, or water content, and a report's silence on a given test is not evidence that the sample passed or failed it.
To find and read the COA that matches your vial, use the batch number printed on the vial or its packaging and locate the matching report in the COA Library.
This product is intended for legitimate laboratory research only. It is not for human use, not for veterinary use, and not for consumption or administration in any form. It is not intended to diagnose, treat, cure, or prevent any disease, and it is not a dietary supplement, food, or cosmetic.
Selank was not listed as an approved drug in the FDA's Drugs@FDA database in the search referenced by Vanta Labs, dated September 24, 2026. A chemical registry entry, such as a CAS number or a PubChem record, identifies the compound for reference purposes and does not indicate regulatory approval of any kind, by the FDA or any other regulatory authority. Buyers are responsible for confirming that their use of this product complies with all applicable laws and regulations in their jurisdiction.
Blog
Store reviews · ordering, shipping and service
5.0 average customer rating
“Ordered on a Wednesday morning and wasn't expecting much because it was my first time buying here. Got tracking that afternoon and the package arrived Friday. Honestly faster than I expected lol.”
Vanta Labs customer
“Not gonna lie I accidentally added the wrong item to my cart and didn't realize until after checkout. Sent a message thinking I'd be stuck with it. Support helped me correct it before the package went out. Saved me a headache.”
Vanta Labs customer
“The packaging was actually what impressed me most. I've had glass research supplies arrive with barely any protection before, so seeing everything packed properly was a relief. Little things like that matter.”
Vanta Labs customer
“First time ordering here. The site was easy enough to use, although I had to go back and double check which size I selected. Everything was labeled clearly when it arrived.”
Vanta Labs customer
“Honestly I spent more time comparing options than I did checking out lol. Once I decided what I wanted, the actual order process took maybe two minutes.”
Vanta Labs customer
“Placed an order after a friend mentioned the website. I was a little skeptical because I hadn't heard of them before, but the ordering experience was straightforward and the communication was good. Everything came fast and will buy again.”
Vanta Labs customer
Sent to us by customers by email; names withheld. Reviews describe ordering, shipping and service.
Specifications
TKPRPGPThr-Lys-Pro-Arg-Pro-Gly-ProSource: PubChem CID 11765600 · ChemicalBook CAS database entry · MedChemExpress Selank data sheet (Cat. No. HY-105042). Accessed 2026-11-13.
Testing
Certificates of Analysis for the batch currently supplied. Each report is the laboratory's own document for that vial size.
KVR-2026-90183D · 10 mg · Batch Vanta184290
Purity 99.254% (RP-HPLC, C18 column, DAD detection at 214 nm) · Identity by LC-MS · Certified Aug 24, 2026 · Kovera Labs
Access code 272ON5R
Kovera Labs reports can be checked with the laboratory: enter the report number and access code at koveralabs.com/verify.
Browse the COA LibraryOrdering: Shipping policy · Returns and reimbursement · Research use disclaimer